Information for the tester
4.3 Technical Data
General:
Microprocessor-controlled instrument for testing
protective measures
Measuring functions:
Voltage, frequency, FI-RCD test, earth/ground
resistance, insulation resistance, loop resistance,
earthing/grounding voltage, rotary field direction,
resistance, continuity check, protective wire
check, phase connection test
Display:
3-digit (999), 19-mm, 7-segment LCD with
additional characters and fluorescent illumination
Operation:
by central selector and function keys
Working temperature range:
-10 °
Operating temperature range:
0 °
Storage temperature range:
-20 °
Reference temperature:
23°C
Intrinsic error:
refers to the reference temperature and is
warranted for 3 years
Operating error:
refers to the operating temperature range and is
guaranteed for 3 years
Temperature coeffizient:
± 0.1% of range / K
Climatic class:
JWG (IEC 654-1) annual mean 65 % RH
Protective type:
IP 40 as per DIN 40050
Security:
Security through double insulation
300 V CATIII, pollution degree 2 as per
IEC/EN 61010-1.-1
Test voltage:
3,7 kV r.m.s as per IEC/EN61010-1
Input protection:
by means of software interlocking, additional
varistors to guard against voltage U
and heavy-duty fuse
6,3 A/380 V/20 kA
EMC (Emission):
IEC61326-1:1997 Class B
CISPR16 (CISPR22), CISPR16-1
...
+ 55 °C
...
+ 35 °C
...
+ 60 °C
± 2 K
> 600 V
rms