Wiring Of Digital Frequency Input / Digital Frequency Output - Lenze EVS9321 Instructions De Montage

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

4.10

Wiring of digital frequency input / digital frequency output

Installation material required from the scope of supply:
Description
Protective cover
Technical data
Field
Connection at drive controller
Pin assignment
Output frequency
Signal
Load capacity
Special features
Internal voltage source
(X10/4, X10/5)
Field
Connection at drive controller
Input frequency
Signal
Signal evaluation
Current consumption
Special features
EDKVS9332X DE/EN/FR 2.0
Wiring of digital frequency input / digital frequency output
Use
Protection for unused Sub-D sockets
Digital frequency output X10
9-pole Sub-D socket
Dependent on the selected basic configuration
0 ... 500 Nm
Two-track with inverse 5 V signals (RS422) and zero track
Maximally 20 mA per channel
(up to 3 slave drives can be connected)
The "Enable" output signal at X10/8 switches to LOW if the drive
controller is not ready for operation (e.g. separated from mains). This can
trip SD3 monitoring on the slave drive.
DC 5 V / max. 50 mA
Total current at X9/4, X9/5 and X10/4, X10/5: max. 200 mA
Digital frequency input X9
9-pole Sub-D socket
0 ... 500 kHz (TTL level)
Two-track with inverse signals and zero track
Via code C0427
Maximally 5 mA
http://www.DataSheet4U.net/
With activated SD3 monitoring, TRIP or warning is tripped if the "Lamp
Control" input signal at X9/8 switches to LOW.
Due to this the drive controller can respond if the master drive is not ready
for operation.
Electrical installation
4
Amount
4
189
datasheet pdf - http://www.DataSheet4U.net/

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Evs9332

Table des Matières