Lenze EVS9321 Instructions De Montage page 112

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

2
Technical data
General data and operating conditions
Operating conditions
Ambient conditions
Climatic
Storage
Transport
Operation
EVS9321 ... EVS9326
EVS9327 ... EVS9332
Pollution
Site altitude
Mechanical
Vibration resistance
Electrical
Mains connection
Mains system
TT, TN
(earthed neutral)
IT
Operation on public
supply systems
Motor connection
Length of the motor
cable
Mounting conditions
Mounting location
Mounting position
Mounting clearances
112
IEC/EN 60721-3-1
1K3 (-25 ... +55 °C)
1K3 (-25 ... +40 °C)
IEC/EN 60721-3-2
2K3 (-25 ... +70 °C)
IEC/EN 60721-3-3
3K3 (0 ... +55 °C)
> +40 °C: reduce the rated output current by 2.5 %/°C.
3K3 (0 ... +50 °C)
> +40 °C: reduce the rated output current by 2.5 %/°C.
EN 61800-5-1
Degree of pollution 2
< 4000 m amsl
Reduce the rated output current by 5%/ 1000 m above 1000
m amsl.
Germanischer Lloyd
General conditions
Unrestricted operation permitted.
Operation permitted with the device variants V104 or V100
only.
Observe instructions concerning specific measures!
61000 DXRA090-3-2
Limitation of harmonic currents
http://www.DataSheet4U.net/
Total power on the mains
< 1 kW
> 1 kW
1)
The additional measures mentioned solely cause the controllers to comply
with the requirements of EN 61000-3-2. The compliance with the requirements
for the machine/system is in the responsibility of the machine/system
manufacturer!
< 50 m
For a rated mains voltage and a switching frequency of 8 kHz,
no additional output filters are required.
If EMC requirements have to be met, the permissible cable
length may be affected.
In the control cabinet
Vertical
 118
< 6 months
> 6 months
> 2 years: anodise DC bus
capacitors
Compliance with the
1)
requirements
With mains choke.
Without additional measures.
EDKVS9332X DE/EN/FR 2.0
datasheet pdf - http://www.DataSheet4U.net/