Electrical Data; Safety Instructions; Fluid Installation - Burkert 6114 Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

ELECTRICAL DATA

Ensure that the polarity is correct, otherwise
the device will not function!
Observe color coding of the cable: (black / red)
Operating voltage
According to type label
Standard version ± 10 %
Clocked version + 10 %
Nominal power
1.1 W
Nominal operating mode Continuous operation, ED 100 %
Actuation of bistable version:
Pulse duration min. 20 ms
Polarity
(black)
Valve (P seat) is
+
closed
Valve (P seat) is
open
english
12
Installation location:
any, drive preferably upwards.
Prior to the installation:
Clean any dirt off the pipelines and flange connections.
To prevent malfunctions, install a filter (5 µm) in front of
the valve.
Assembly of Type 6114:
(See diagram: Assembly drawing)
WARNING!
Danger - escaping medium!
Leaking connections if seal seated incorrectly.
• Ensure that the supplied sealing gasket is seated
correctly.
Insert the sealing gasket into the valve.
Correctly allocate the fluid connection configuration 1,
2 and 3 to the valve and the connection plate.
Drill holes according to the drill hole-pattern.
Screw valve onto the connection plate
Check valve for leakage.
english
14
Identification
(red)
Valve (R seat) is
open
Valve (R seat) is
closed
INSTALLATION

Safety Instructions

WARNING!
Risk of injury from improper assembly!
• Installation may be carried out by authorised technicians
only and with the appropriate tools!
Risk of injury from unintentional activation of the
system and an uncontrolled restart!
• Secure system from unintentional activation.
• Following assembly, ensure a controlled restart.

Fluid Installation

WARNING!
Risk of injury from high pressure!
• Before loosening the lines and valves, turn off the pressure
and vent the lines!
Important operating condition for the preven-
tion of malfunctions: The valve must have a mini-
mum distance of 5 mm from other ferromagnetic
materials.
Valve with fastening elements
Bore hole
illustration:
Fluid connections
(see "Pneumatic data")
Bores for fastening
screws
Ø 2 mm
Figure: Assembly drawing
Type 6114
english
13
6
2,25
2
1
1,1
3,7
8,1
9,1
6,2
Sealing gasket