18
4.0 INSTALLATION
4.0 INSTALLATION
EN
ENSURE TO UNPACK ALL LOOSE MATERIALS FROM INSIDE THE FIREBOX PRIOR TO HOOKING UP
ENSURE TO UNPACK ALL LOOSE MATERIALS FROM INSIDE THE FIREBOX PRIOR TO HOOKING UP
IF YOUR APPLIANCE IS SUPPLIED WITH A REMOTE, ENSURE THE REMOTE RECEIVER IS IN THE
IF YOUR APPLIANCE IS SUPPLIED WITH A REMOTE ENSURE THE REMOTE RECEIVER IS IN THE
"OFF" POSITION PRIOR TO HOOKING UP THE GAS AND ELECTRICAL SUPPLY TO THE APPLIANCE.
"OFF" POSITION PRIOR TO HOOKING UP THE GAS AND ELECTRICAL SUPPLY TO THE APPLIANCE.
FOR SAFE AND PROPER OPERATION OF THE APPLIANCE, FOLLOW THE VENTING INSTRUCTIONS
FOR SAFE AND PROPER OPERATION OF THE APPLIANCE, FOLLOW THE VENTING INSTRUCTIONS
ALL EXHAUST AND INTAKE VENT PIPE JOINTS MUST BE SEALED USING RED RTV HIGH TEMP
ALL INNER EXHAUST AND OUTER INTAKE VENT PIPE JOINTS MAY BE SEALED USING EITHER RED
SILICONE SEALANT (W573-0002) (NOT SUPPLIED) OR BLACK HIGH TEMP MILL PAC (W573-0007)
RTV HIGH TEMP SILICONE SEALANT W573-0002 (NOT SUPPLIED) OR BLACK HIGH TEMP MILL PAC
(NOT SUPPLIED) WITH THE EXCEPTION OF THE APPLIANCE EXHAUST FLUE COLLAR WHICH MUST
W573-0007 (NOT SUPPLIED) WITH THE EXCEPTION OF THE APPLIANCE EXHAUST FLUE COLLAR
IF USING PIPE CLAMPS TO CONNECT VENT COMPONENTS, A MINIMUM OF 3 SCREWS MUST ALSO
IF USING PIPE CLAMPS TO CONNECT VENT COMPONENTS, 3 SCREWS MUST ALSO BE USED TO
RISK OF FIRE, EXPLOSION OR ASPHYXIATION. IMPROPER SUPPORT OF THE ENTIRE VENTING
RISK OF FIRE, EXPLOSION OR ASPHYXIATION. IMPROPER SUPPORT OF THE ENTIRE VENTING
SYSTEM MAY ALLOW VENT TO SAG AND SEPARATE. USE VENT RUN SUPPORTS AND CONNECT
SYSTEM MAY ALLOW VENT TO SAG AND SEPARATE. USE VENT RUN SUPPORTS AND CONNECT
RISK OF FIRE, DO NOT ALLOW LOOSE MATERIALS OR INSULATION TO TOUCH THE VENT PIPE.
RISK OF FIRE, DO NOT ALLOW LOOSE MATERIALS OR INSULATION TO TOUCH THE VENT PIPE.
REMOVE INSULATION TO ALLOW FOR THE INSTALLATION OF THE ATTIC SHIELD AND TO
REMOVE INSULATION TO ALLOW FOR THE INSTALLATION OF THE ATTIC SHIELD AND TO
4.1
MINIMUM CLEARANCE TO COMBUSTIBLES
4.1
MINIMUM CLEARANCE TO COMBUSTIBLES
As long as clearance to combustibles is kept within required distances, the most desirable and beneficial location for an
As long as clearance to combustibles is kept within required distances, the most desirable and benecial location for an appli-
appliance is in the centre of a building, thereby allowing the most efficient use of the heat created. The location of windows,
ance is in the centre of a building, thereby allowing the most ef cient use of the heat created. The location of windows, doors
doors and the traffic flow in the room where the appliance is to be located should be considered. If possible, you should
and the traf c ow in the room where the appliance is to be located should be considered. If possible, you should choose a
choose a location where the vent will pass through the house without cutting a floor or roof joist.
location where the vent will pass through the house without cutting a oor or roof joist.
MAINTAIN THESE MINIMUM CLEARANCES TO COMBUSTIBLES:
MAINTAIN THESE MINIMUM CLEARANCES TO COMBUSTIBLES:
A. 7" (17.8mm)
A. 7" (178mm)
D. 17 1/2" (445mm)
D. 17 1/2" (445mm)
B
BACK WALL
E
Minimum 20" (508mm) from appliance top to ceiling
Minimum 20" (508mm) from appliance top to ceiling
* At a distance of 1" (25mm) from the wall, access to the blower switch, on-off switch or the blower power
* At a distance of 1" (25mm) from the wall, access to the blower switch, on-off switch or the blower power cord
cord may not be practical.
may not be practical.
GDS50:
GDS50:
HORIZONTAL VENT SECTIONS: A minimum clearance of 2" (51mm) at the top and 1" (25mm) at the bottom
HORIZONTAL VENT SECTIONS: A minimum clearance of 2" (51mm) at the top and 1" (25mm) at the bottom
and sides of the vent pipe on all horizontal runs is required.
and sides of the vent pipe on all horizontal runs is required.
VERTICAL VENT SECTIONS: A minimum of 1" (25mm) all around the vent pipe on all vertical runs to
VERTICAL VENT SECTIONS: A minimum of 1" (25mm) all around the vent pipe on all vertical runs to
combustibles is required.
combustibles is required.
GDS50:
GS50:
A minimum of 1" (25mm) all around the B-vent pipe on both horizontal and vertical runs to combustibles is
A minimum of 1" (25mm) all around the B-vent pipe on both horizontal and vertical runs to combustibles is
required
required.
W415-1427 / 12.23.14
!
THE GAS AND ELECTRICAL SUPPLY.
THE GAS AND ELECTRICAL SUPPLY.
BE SEALED USING MILL PAC.
WHICH MUST BE SEALED USING MILL PAC.
BE USED TO ENSURE THE CONNECTION CANNOT SLIP OFF.
ENSURE THE CONNECTION CANNOT SLIP OFF.
DO NOT CLAMP THE FLEXIBLE VENT PIPE.
DO NOT CLAMP THE FLEXIBLE VENT PIPE.
VENT SECTIONS PER INSTALLATION INSTRUCTIONS.
VENT SECTIONS PER INSTALLATION INSTRUCTIONS.
MAINTAIN CLEARANCES TO COMBUSTIBLES.
MAINTAIN CLEARANCES TO COMBUSTIBLES.
B. 2" (51mm)
B. 2" (51mm)
E. 6 1/4" (159mm)
E. 6 1/4" (159mm)
A
A
D
WARNING
WARNING
!
EXACTLY.
EXACTLY.
C. 1" (25mm)*
C. 1" (25mm)*
F. 9 1/2" (241mm)
F. 9 1/2" (241mm)
B
A
ALCOVE
19
68.2B
BACK WALL
45°
F
W415-1427 / B / 08.01.18
EN
C