Deleting Data From The Control Unit Memory - Nice Shel50Kit Instructions Et Avertissements Pour L'installation Et L'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 23
Notes to Table 4:
– The Table states the values available for each of the 4 special functions and
the corresponding key to be pressed on the transmitter for selection of the spe-
cific value.
– The factory settings are highlighted in grey.
AUTOMATIC CLOSURE
No closure —> (press key "T1")
Closure after 15 seconds —> (press key "T2")
Closure after 30 seconds —> (press key "T3")
Closure after 60 seconds —> (press key "T4")
MOVEMENT SPEED
Low Opening / Low closing —> (press key "T1")
Low Opening / Fast closing —> (press key "T2")
Fast Opening / Low closing —> (press key "T3")
Fast Opening / Fast closing —> (press key "T4")
SENSITIVITY TO OBSTACLES
High —> (press key "T1")
Medium high —> (press key "T2")
Medium low —> (press key "T3")
Low —> (press key "T4")
PRESSURE DISCHARGE
No discharge —> (press key "T1")
Minimum —> (press key "T2")
Medium —> (press key "T3")
Maximum —> (press key "T4")
11 – MEMORISING A NEW TRANSMITTER WITH PROCEDURE
IN THE VICINITY OF THE CONTROL UNIT
[with a transmitter already memorised]
A NEW transmitter can be memorised in the control unit memory without acting
directly on key P1 of the control unit, but by simply working within its reception
range. To use this procedure, an OLD transmitter, previously memorised and
operative, is required. The procedure enables the NEW transmitter to receive
the settings of the OLD version.
Warning – The procedure must be performed within the reception range
of the receiver (maximum 10-20 m from receiver).
01. On the NEW transmitter, press and hold the key to be memorised for at
least 5 seconds and then release.
02. On the OLD transmitter, slowly press the control key to be memorised on
the other transmitter 3 times.
03. On the NEW transmitter, press the same key pressed in point 01 once.
Note – Repeat the same procedure for each key to be memorised.
12 – DELETING DATA FROM THE CONTROL UNIT MEMORY
Data in the control unit memory can be deleted partially or totally as required. To
do this, the following procedures can be used, as required:
• Deletion of a command on a transmitter already memorised
• Deletion of other data memorised on the control unit
Deleting a command on a transmitter already memorised
The following procedure enables deletion of a single command assigned to a
transmitter key from the control unit memory.
Note – During the procedure, the red and green leds remain permanently lit.
01. Press and hold the key "P1" on the Control unit for at least 10 seconds: the
green Led illuminates first, then the red led illuminates after 5 seconds and
then both, to indicate that the Control unit has entered memory deletion
mode (WARNING! do not release the key P1!).
02. Without releasing key P1 press the transmitter key to be deleted: if the
control unit recognises this operation, the green led emits a short flash,
after which the P1 key and transmitter key can be released.
TABLE 4
Deleting other data memorised on the control unit
The following procedure enables deletion of various types of memorised data
from the control unit memory, as specified in Table 5.
Note – During the procedure, the red and green leds remain permanently lit.
01. Press and hold the key "P1" on the Control unit for at least 10 seconds:
the green Led illuminates first, then the red led illuminates after 5 seconds
and then both, to indicate that the Control unit has entered memory dele-
tion mode. Then release the key.
02. With reference to Table 5, select the data to be deleted and press P1 the
same number of times as the number of presses specified in brackets (the
green led emits one flash each time the P1 key is pressed).
03. 5 seconds after the key "P1" is pressed for the last time, if deletion is suc-
cessful, both leds (red and green) flash quickly (= memory deleted!).
Note – Before deletion, there is a margin time of 5 seconds, in which the
user has the option to change decision and exit the procedure without
deleting data by pressing key P1 five times.
IMPORTANT! - After deletion of the "Memory of Closing and Opening limit
positions" and "TOTAL Memory", the procedure 9.2 – "Learning the Closing
and Opening limit positions" must be repeated.
• Memory of Optional Function values (= 1 press)
• Memory of "Closing " and "Opening" limit positions (= 2 presses)
• Memory of Transmitters (= 3 presses)
• TOTAL memory (= 4 presses) Note – deletes the first three memories in
one process
TABLE 5
English – 7

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Shel75kit

Table des Matières