Code Parameter
Microphone signal amplification (without additional amplifier): Default
912
setting: 0/0
0 = 0 dB
1 = 6 dB
2 = 12 dB
3 = 18 dB
Microphone signal amplification (with additional amplifier): Default
922
setting: 0/0
0 = 0 dB
1 = 6 dB
2 = 12 dB
3 = 18 dB
Deviating configuration steps for universal devices
(20-0005/-0006/-0018/-0026/-0028A/-0028B/-0048)
21
Telephone number for button 1
22
Telephone number for button 2 or MLM A respectively (yellow socket)
23
Telephone number for button 3 or MLM B respectively (blue socket)
24
Telephone number for button 4 or MLM C respectively (red socket)
25
Telephone number for button 5
:
:
28
Telephone number for button 8
29
Telephone number for button
Further configuration steps, such as relay control, acoustic settings, add-on electronics,
voice message / real time clock, etc. can be found in the extensive technical manual (www.
behnke-online.de/handbuch-analog).
www.behnke-online.com