12 - LOADING THE DEFAULT PARAMETERS

If necessary, it is possible to restore all parameters to their standard or default values (see the final summary table).
PLEASE NOTE: This procedure results in the loss of all customised parameters, and hence it has been included outside the
configuration menu, in order to minimise the likelihood of it being run in error.
1. Press and hold the OK key until the display shows -dEF
2. Release the OK key: the display shows ESC (only press the OK key if it is desired to exit this menu)
3. Press the i key: the display shows dEF.
4. Press the OK key: the display shows no
5. Press the i key: the display shows Si
6. Press the OK key: all parameters are overwritten with their default values (see Chapter 17.2), the control units exits programming
mode and the display shows the control panel.
13 - INSTALLATION MENÙ (SEt)
This menu allows to move the door as required during installation.
The automatic self-teaching procedure allows to store the positions of the limit switch sensors and of the opening and closing slow-down
starting points.
The manual handling procedure allows to control the door in hold to run mode in special cases such as during installation/maintenance or
a malfunction of the photocells or edges
CAUTION: ATTENTION: before proceeding, make sure to position the mechanical stops and the limit sensors correctly.
1. Press and hold the OK key until the display shows -SEt
2. Release the OK key: the display shows ESC (only press the OK key if it is desired to exit this menu)
and i to select the menu Mov to activate manual handling or APPr to start the automatic learning procedure
3. Use the keys
of the run limits.
4. Press OK to start the selected procedure