Start command during the closing phase
This menu allows fixing the control unit conduct in case it receives a
Start command during the closing phase.
StoP
The door stops and its cycle is considered as finished
APEr
The door opens again
Select option StoP, to set up the "step-by-step" operation logic.
Select option APEr, to set up the 'always open' operation logic.
Start command during the pause
This menu allows fixing the control unit conduct in case it receives a
Start command when the door is open during its pause phase.
ChiU
the door starts closing
no
command is ignored
PAUS
The pause time is restarted (Ch.AU)
Select option ChiU, to set up the "step-by-step" operation logic.
Select option 'no', to set up the 'always open' operation logic.
Apart from selected option, the start command lets the door
close if it has been stopped by a stop command or if the
automatic closing was not enabled.
Automatic closing
During the automatic operation, the control unit will automatically close
the door when a set-up time expires.
The Start command, if enabled by St.PA menu, allows closing the door
before the set up time expires.
In semi-automatic operation, that is to say, if the automatic closing
function is disabled by setting the value to zero ('no' will be displayed),
the door can be closed through the start command only: in this case,
St.PA menu setup will be ignored.
If the control unit receives a Stop command when the door is in
pause, it will automatically pass to the semi-automatic operation.
Closing after transit
During the automatic operation, the pause count down starts from the
set up value each time a photocell operates during the pause.
If the photocell operates during the opening time, this time will be
immediately stored as pause time.
This function allows having a fast closing as soon as transit through
the door is completed, therefore, a time shorter than CH.AU is
generally used.
Ch.AU will be used when 'no' is set up.
As for semi-automatic operation, this function is not active.
62