Motor power during closure
This menu allows to adjust the motor power during closure.
The displayed value represents the percentage with respect to the
maximum motor power.
Motor power during slow-down at opening
This menu allows to adjust the motor power during the opening
slow-down.
The displayed value represents the percentage with respect to the
maximum motor power.
Motor power during slow-down at closure
This menu allows to adjust the motor power during the closure slow-
down.
The displayed value represents the percentage with respect to the
maximum motor power.
Start off
When the door is standstill and it begins moving, the initial inertia
must be faced, therefore, if your door is quite heavy, it could not move.
If the Sstart off function is activated, for the first 2 seconds of motion of
each door, the control unit will ignore P.AP value and it will give motor
the maximum power command in order to overcome the door inertia.
Starting ramp
In order not to stress too much the motor, when the motion starts the
power is gradually increased, until reached the set value or 100% if the
take-off is enabled.
Higher is the set value, longer the length of time of the ramp, that is the
time necessary to reach the value of nominal power.