8.5 - PHOTOCELL

PD15 control unit supplies a 24Vdc power supply to photocells
and it can perform a photocell operation test before starting
the door opening phase. Photocell power terminals are
protected by an electronic fuse that stops current in case of
overload.
The photocells are active only during the closing phase and, if
required, with standstill door. In case intervention, the control
unit immediately opens the door, not waiting for the release.
• Connect power supply cables of photocells transmitter
between terminals J7 (COM) and J8 (+) of the control unit.
• Connect power supply cables of photocells receiver between
terminals J6 (+) and J7 (COM) of the control unit.
• Connect N.C. receiver output between terminals J4 and J5 of
the control unit. Use outputs having normally closed contact.
WARNING:
• If several couples of photocells are mounted, their outputs
must be connected in series.
• In case of reflection photocells, power supply must be
connected to terminals J7 and J8 of the control unit to
carry out the operation test.

8.6 - STOP

For a better safety, you can fit a stop switch that will cause the
immediate door stop when activated. This switch must have a
normally close contact that will get open in case of operation.
In case the stop switch is operated while the door is open, the
automatic closing function will always be disabled. To close the
door again, you will need a start command (if the start function
in pause is disabled, it will be temporarily enabled to allow the
door release).
Connect the stop switch cables between terminal J3 and J4 of
the control unit.
The stop switch function can be activated by means of a
remote control stored on channel 3 (see relevant instructions
of MR2 receiver).

8.7 - ACTIVATION INPUT

The PD15 central unit has an activation input
with N.A. contact that can be activated using
the pushbutton found on the motor lid or using
a transmitter (the pushbutton should be tuned
to channel 1 on the MR2 receiver).
Use the J2 and J4 clamps to connect up an
external pushbutton.

8.8 - EXTERNAL AERIAL

We suggest to use the external aerial (model: ANS433) in
order to guarantee the maximal range.
Connect the antenna hot pole to terminal A2 of the control unit
and the braiding to terminal A1.

8.9 - PLUG IN RECEIVER

PD15 control unit is suitable for plugging in a Personal Pass
MR2 receiver having a high-sensitivity super-heterodyne
architecture.
WARNING: it is necessary to turn off the control unit
power before doing the operations mentioned here below.
Pay attention to the way you connect the removable
modules.
MR2 module receiver is provided with 4 channels and each of
them is suitable for a command of PD15 control unit:
• CHANNEL 1
START
• CHANNEL 2
NOT USED
• CHANNEL 3
STOP
• CHANNEL 4
COURTESY LIGHT
WARNING: Before programming 4 channels and function
logics read carefully the instructions of MR2.