Automatic Learning Of The Run Limits; Manual Handling - V2 VEGA-24V Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

13.1 - AUTOMATIC LEARNING OF THE RUN LIMITS

CAUTION: to perform the self-learning procedure it is necessary to disable the ADI interface by means of the menu i.Adi .
If some safeties are controlled by means of the ADI module, they will not be active during the self-teaching stage.
5. Adjust the limit switch cams in the maximum opening and closing positions.
6. The display shows the control panel and the automatic learning procedure of the run limits starts:
6.1
The door is closed until it comes into contact with the stopper, until it reaches the closing limit switch or until
the UP button is pressed
6.2
The door is opened until it comes into contact with the stopper, until it reaches the opening limit switch or until
the UP button is pressed
6.3
The door is closed until it comes into contact with the stopper, until it reaches the closing limit switch or until
the UP button is pressed
7. The display shows the recommended value for the obstacle sensor. If no operations are performed for 20 seconds, the control unit exits
the programming phase, without saving the value recommended.
8. The recommended value may be modified by pressing the
display shows SEnS
9. Press and hold the i key until the display shows FinE, then press the OK key, select the option Si and then press the OK key to exit
programming mode, storing the value for the sensors.
PLEASE NOTE: If the control unit is left to time out from programming mode (1 minute), the obstacle sensor return to
the value that was set prior to performing self-training (according to the default values the sensor is 7.5A).
On the other hand, the limit switch positions are always stored.

13.2 - MANUAL HANDLING

WARNING: when this procedure is activated the safeties are not active.
5. The display shows MAn
key to open the door or the i button to close the door
6. Press and hold the
7. Release the button to stop the door
8. To exit this menu, press OK.
NOTE: If the motor is inactive for more than one minute the procedure terminates automatically.
and i keys, and pressing the OK key confirms the displayed value and the
example
55

Publicité

Table des Matières
loading

Table des Matières