DISPLAY
DATA
DESCRIPTION
AUS
Auxiliary channel
tiM
- Timed function (from 0 to 20')
biSt
- Bistable operation
Mon
- Monostable operation
SPiA
Setting low voltage exit lights
no
- Not used
FLSh
- Flasher operation (fixed frequency)
W.L.
- Indicator light operation: indicates the status of the door in real-time
LP.PA
no / Si
Blinker during pause time
Strt
Start input function
StAn
- Standard operation
no
- Start inputs from terminal board are disabled
StoP
STOP input
no
- STOP input not available
invE
- STOP command stops the door: START command starts moving in the opposite direction
ProS
- STOP command stops the door: pressing the START command door continues the motion
Foto
Photocell input
CFCh
- Photocell is active in closing and also when the door is still
no
- Not available
Ch
- Photocell is active during the closing
Ft.tE
no / Si
Test of the photocells
CoSt
Safety ribbon input
no
- Input disabled
AP
- Input enabled only in opening phase
Ch
- Input enabled only in closing phase
APCh
- Input enabled in opening and closing phase
Co.tE
Test of the safety edges
no
- Test disabled
rESi
- Test enabled for conductive rubber safety edges
Foto
- Test enabled for optical safety edges
FC.En
Limit switch input
StoP
- the door stops by the limit switches
rALL
- the door begins the slow-down stage (t.rAL menu) by the limit switches
- the "shadow area" function is activated when the LEFT micro switch trips and disabled
ShAd
when the RIGHT micro switch trips
no
- Inputs disabled
riLA
0 ÷ 10
Motor release on mechanical stop
i.Adi
no / Si
Enabling the ADI device
CFG
Mt / SL
Control unit setting
FinE
End programming.
no
- Do not exit the programming menu
Si
- Exit from the programming menu, storing the parameters set
69
MEMO
DEFAULT
DATA
tiM
W.L
no
StAn
no
CFCh
no
no
no
StoP
2
no
Mt
no