Electrical Wiring Installation - Zephyr DLI-E30ASX Mode D'emploi

Hotte de ventilation à aspiration descendante
Masquer les pouces Voir aussi pour DLI-E30ASX:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

DBI-600A Blower only
CAUTION
All electrical wiring should be done by a qualified
person(s) in accordance with all applicable codes
and standards.
• This downdraft blower using the DBI-600A Blower (purchase
separately) draws 3.0 Amps and requires a
120 VAC, 60 Hz circuit.
• The unit has a 30 in. long power cord with a 3-pronged plug
attached to the electrical panel. Plan to provide a grounded
outlet in a location which will allow the unit's power cord to
reach.
• Install electrical box according to local codes.
18a
Mount a standard wiring box, with 3-pronged receptacle, within reach
of downdraft's power cord. (Run appropriate power cable and connect it
to receptacle.)
19a
I
Remove electrical panel (I) cover and route blower wire into wiring box.

Electrical Wiring Installation

White (common)
Blue (low)
Lift
Grey (med.)
Downdraft
Black (high)
Orange (high)
Green (ground)
20a
Connect blower wires to wires in electrical panel. Replace electrical
panel cover.
Note: Orange wire from blower is capped off and not connected.
21a
21a
Plug electrical panel cable into lower receptacle on side of downdraft.
22a
Plug downdraft's power cord into outlet.
Note: Make sure that power cord is routed away from the heat
generated by the cooktop.
17
White (common)
Blue (low)
DBI-600A
Red (med.)
Blower
Black (high)
Green (ground)
Orange (Capped Off)