Sentiotec infrabox basic Instructions De Montage Et Mode D'emploi page 41

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Instructions for installation and use
The Infrabox Basic infrared controller is suitable for use with intrinsically
safe infrared heaters and infrared plates. If no intrinsically safe products
are being used, a safety temperature limiter must be connected.
● If infrared heaters are connected, they must have a safety temperature limiter.
For suitable infrared heaters see 2.1. Intended use on page 5.
If infrared plates are connected, the WC4-IRF-F foil sensors must be used
and activated (see 4.3. Installing the foil temperature sensor on page 13
and 5.3. Connecting the foil sensor (optional) on page 16). For suitable
infrared plates see 2.1. Intended use on page 5.
Automatic heating period limiter
The infrared controller shuts down automatically after the maximum heat-
ing period for safety reasons (see also 6.3. Operating time on page 20).
!
The EN 60335-2-53 specifies a maximum heating period limit of 6 hours
for private infrared cabins. For infrared cabins in hotels, apartment blocks
and similar locations, a maximum heating period limit of 12 hours is
permissible. Extending the heating period limit to 18 hours or 24 hours
is only permitted in public infrared cabins.
p. 9/32
EN

Publicité

Table des Matières
loading

Table des Matières