12.2 EDS 3000 WITH THIN FILM DMS SENSOR CELL; RELATIVE PRESSURE
STARTING AT 40 BAR
Design (technology)
4
= Thin film DMS relative
Type of connection, mechanical
4
= G1/4 A ISO1179-2, male (DIN 3852)
9
= Port DIN 3852-G1/4
Type of connection, electrical
6
= Device plug M12x1, 4 pole (connector not supplied)
only possible on output models „1", „2" and „3"
8
= Device plug M12x1, 5 pole (connector not supplied)
only possible on output model "5" and
modification number "V02"
Output
1
= 1 Switch output
only in conjunction with electrical connection type "6"
2
= 2 Switch outputs
only in conjunction with electrical connection type "6"
3
= 1 Switching and 1 analogue output
only in conjunction with electrical connection type "6"
5
= 2 Switching outputs and 1 analogue output
only in conjunction with electrical connection type "8" and
modification number "V02"
Pressure range in bar
040;100; 250; 400; 600
Modification number
V00 = Menu navigation in accordance with VDMA (standard sheet 24574-1)
V02 = Menu navigation in the style of VDMA (standard sheet 24574-1)
EDS 3 X X X - X - XXXX - V0X