When it is being used outdoors, the DuoControl must
be protected from the elements and dripping water
with a protection hood.
Choose a suitable position for the DuoControl, in particular:
– Type plate legible,
– Status indicator recognisable,
– Avoid damage during cylinder replacement,
– Make it difficult for gas in the liquid phase to penetrate,
– Allow enough room to retrofit the Truma remote indicator,
– Route high-pressure hoses without tension.
– If the gas cylinder valves are more than one metre apart,
the additional kit (part no. 50020-61100) may be used.
Figure 6
– Fasten to a stable wall / ceiling with 4 screws.
Ensure that it is firmly attached.
20
> 100 cm
– Screw high-pressure hoses to the DuoControl inlets, using
elbow unions (part. no. 50020-56000) if necessary.
– When installation is complete, have the entire gas system
inspected by a specialist technician to check for leaks and
correct installation. Check the hose connections at the
DuoControl inlet for leaks (e.g. using a leak-finder spray in
accordance with EN 14291).
This test does not replace the regularly scheduled gas
check!
– All functions must then be tested in accordance with the
operating instructions.
– The operating instructions must be given to the operator.

Sticker

In vehicles from construction date 01/2007, the gas cylinders
must be closed while driving when using the DuoControl gas
pressure regulation system.
– The supplied stickers must be applied in the cylinder box
and close to the control panel for the liquid gas heater.