Assembly
5
In this step, the halyard swivel, feeder and torque tube are attached to the foil.
Long Hooked
Tang Up
Norseman/Sta-Lok Instructions
After the swivel and torque tube have been placed on the wire
you must install the Norseman or Sta-Lok terminal. For easier
installation, push the bottom foil completely over the bottom
connector to expose as much wire as possible. After the termi-
nal is attached, secure the bottom foil as described in Step 4.
January 2002
Slip the halyard swivel onto the foil and up past the 1
(41 mm) gap in the foils.
The halyard swivel has a "top" and a "bottom" and must
be placed on the foil with the long hooked tang facing up.
Tip: When positioned correctly, the small Harken label will be right
side up.
NORSEMAN, STA-LOK OR ROD - refer to special
STOP
instructions below before proceeding.
Attach the feeder to the gap in the foils. Use blue Loctite
on the screw. The end of the feeder with the screw
should be at the bottom of the gap.
Tip: The feeder uses a "loose hinge." Place the half with the pin
sockets into place on the exposed connector, slip the half with the
pins into the sockets and snap it shut.
Slip the torque tube cap onto the foil, open end down.
Slip the drum assembly onto the foil until it stops. The
top of the torque tube will be 15" (380 mm) from the
bottom of the feeder.
Tip: Rubber band line to the torque tube to keep out of the way.
Rod Instructions
After the swivel has been attached per the above instructions,
you must attach the rod terminal to the rod.
Unit 00AL
/
"
5
8
35