Preassembly
Pin-to-Pin Headstay Length (See Pg 8)
Longueur axe à axe de l'étai (Voir Pg 8)
Bolzen-Bolzen-Mass Anzahl des Vorstages (s.S. 8)
Lunghezza perno-a-perno dello strallo (vedi p. 8)
17'6" to 18'2" (5.334 m to 5.537 m)
18'3" to 25'2" (5.563 m to 7.671 m)
25'3" to 32'2" (7.696 m to 9.804 m)
32'3" to 35' (9.830 m to 10.668 m)
17'6" to 24'6" (5.334 m to 7.468 m)
24'7" to 31'6" (7.493 m to 9.601 m)
31'7" to 35' (9.627 m to 10.668 m)
Norseman/Sta-Lok Instructions
Because Norseman and Sta-Lok terminals are applied to the
headstay wire after the foil is built, it is not necessary to place
the connectors or trim cap on the wire at this time.
Norseman and Sta-Lok units require the same number of foils
and connectors as shown above. Identify the parts you need
and set them aside at this time.
June 1999
Number 6" (152 mm) Connectors
Nombre de connecteurs de 152 mm utilisée
Anzahl benötigter Verbinder von 152mm
Numero di estrusi da 152 mm usati
2
3
4
5*
Number 7' (2.13 m) Foils Used
Nombre de profils de 2.13 m utilisée
Anzahl benötigter Profile von 2.13m
Numero di estrusi da 2.13 m usati
2
3
4*
How many foils and connectors • Stringing connectors
■ How Many Connectors?
Use the chart at left to determine the proper number
of 6" (152 mm) connectors for your headstay.
Every unit uses one 7
addition to the number of 6" (152 mm) connectors
shown at left.
*One additional connector required; order part #909
■ How Many Foils?
Use the chart at left to determine the proper number
of 7' (2.13 m) foils for your headstay.
The variable length top foil is cut from one of the 7'
(2.13 m) foils and is used in addition to the number
of foils shown at left.
*One additional foil required; order part 1112.
■ Stringing Connectors
After the headstay has been cut to length, but before the
lower terminal is attached, the proper number of con-
nectors must be placed on the headstay in the correct
order.
Every unit uses a top foil trim cap.
Every unit uses a number of 6" (152 mm) connectors
which varies according to the length of the headstay
and is determined by consulting the chart above.
Every unit uses one 7
Slide the trim cap onto the stay so that the open end
faces down.
Slide the proper number of 6" (152 mm) connectors
onto the headstay.
Slide the 7
/
" (194 mm) bottom connector onto the
5
8
headstay so that it is closest to the bottom of the
headstay.
Have the wire swaged by a reputable rigger.
Rod Instructions
Rod installations are identical to swaged wire at this point
except that the rod fitting is "coldheaded" to the rod rather than
swaged on.
If you ship a rod headstay to a service center do not coil tighter
than 200 times the rod's diameter.
Unit 00AL
/
" (194 mm) bottom connector in
5
8
/
" (194 mm) bottom connector.
5
8
17