SECTION 4
WARNING
BE SURE to tighten fittings securely using 2 wrenches during reassembly. (Factory
recommended torque is 3.39 n-m or 30 in-lbs). Failure to do so could result in seri-
ous injury to the operator.
Pull flex support back. Remove
1
tape holding splices.
Unscrew handle and
power cable from head
Figure 4-1 Power Cable and Switch Disassembly Sequence
Slide switch and band from handle.
2
Snip leads at splice to replace
switch.
3
84