Maintenance; Repositioning Torch Switch - ESAB PT-31XL Manuel D'instruction

Masquer les pouces Voir aussi pour PT-31XL:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 138
SECTION 4

4.1 MAINTENANCE

The power cable and switch leads in the service line should be inspected periodically. If there are any cuts through the pro-
tective sheath or if gas leaks are noted, replace the damaged component.
WARNING
4.1.1
Disassembly of Service Line (refer to Figure 4-1)
1.
Lay the line out straight.
2.
Pull flex support back and remove the tape from around the switch lead splices.
3.
Free the switch by cutting the leads close to the splices.
4.
Replacement switches have extra long leads to make up for any loss due to cutting.
5.
Remove the rubber boot from the inlet end of the cable.
6.
Remove the tape that secures the sheath at each end.
7.
Pull the sheath off the cable (over small fitting at torch end).
The switch leads wrapped around the power cable are secured with tape several places along the cable.
WARNING
8.
The leads, switch cord plug, and strain relief can now be removed. See Figure 4-1, Step 3.
CAUTION
9.
Reassemble in reverse order.
4.2

Repositioning Torch Switch

In some applications it is more convenient for the troch switch to be positioned 180 degrees from current configuration.
To reposition the switch on the torch, slide the flex support back, remove the tape securing the spliced leads to the power
cable, reposition switch, retape the leads, and pull the flex support back in place. See Figure 4-1.
A thin film of silicone lubricant P/N 0558000443 (17672), supplied with the spare parts kit, applied inside of
Before any maintenance is attempted on this torch, make sure the POWER SWITCH
on the power source is in the OFF position and the PRIMARY INPUT POWER is
DEENERGIZED.
Note
BE SURE to loosen fittings using 2 wrenches during disassembly. Failure to do so
could result in serious injury to the operator.
DO NOT remove the white tape that forms a band around the power cable at each
end. The sheath is taped to the cable in front of the band which acts as a shoulder
to prevent the sheath from sliding back on the cable. Replacement cables have
this tape in place.
If the switch leads are to be replaced, replace with 16 AWG STRANDED COPPER,
600- VOLT, 90
C (194
F) INSULATED WIRE.
°
°
Note
the flex support will ease the assembly of this part.
83
MAINTENANCE

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Pt-31xlpc36285

Table des Matières