Turning The Machine On - Eureka Mignon MEB Manuel D'instructions

Masquer les pouces Voir aussi pour Mignon MEB:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Chute, until it is in contact with the micro-switch button (6), or continue to press the
side activation button (24/25), in order to dispense the ground coffee from the
Spout (5).
• To stop dispensing ground coffee, move the Filter Holder or Ground Coffee Basket
away from the micro-switch (6) or release the side button (24/25).
5.3
TIMER MODE FUNCTION
• Lay the Filter Holder on the Fork (10/11/12) (Fig. 9) or position the ground coffee
basket (13) under the outlet chute (5)(Fig.10).
• Push the filter holder, or the Ground Coffee Basket, until it is in contact with the
micro-switch button (6), in order to dispense the ground coffee from the Spout (5).
• To set the dispensing time, turn the potentiometer (23) to either increase or decrease
the quantity of coffee grounds.
• Dispensing stops at the end of the set time. To stop dispensing before the time is
over, push the micro-switch button (6) again.
If the appliance is equipped with the Select Button (22), it is possible to switch
from Manual to Timer Mode (and Timer to Manual Mode). To activate Manual
Mode, push the « M » positioned button ; to activate Timer Mode, press the « T »
positioned Button.
5.4
DISPLAY FUNCTIONING
5.4.1

TURNING THE MACHINE ON

When starting the machine for the first time, the appliance has the factory default
settings. In the subsequent starts, it keeps the settings preceding the last use
before it was switched off.
When starting, the display loads the firmware and gets ready for dispensing.
5.4.2
DOSE DISPENSING AND ADJUSTMENT (DISPLAY)
• To select the dose that is to be dispensed, select one dose (18)
dose (19)
,button on the display screen. Once selected, the dose button will be
illuminated.
• The dispensing of coffee grounds and the countdown to zero are activated with a
single press of the Start Button (6).
• Once the dispensing is complete, the Grinding Time will return to the original value at
which it is set. The counter of single or double doses is increased by 1.
• Select the single (18)
34
or double dose (19)
or double
and use the Buttons (16)
EN