Heating Slim Receiver io 2kW
2.5. SETTING THE TIME OF FUNCTIONING
The operating duration of the heating lamp before automatic shut-down can be configured.
The default setting is 6 hours.
To change this setting:
1) Briefly press the my and Down buttons simultaneously on the
io local control point.
2) Just afterwards, press the my and Down buttons simultaneously
and keep depressed until the heating lamp turns on then turns
off.
• Briefly press the Down button to set the duration to 3 hours.
• Briefly press the my button to set the duration to 6 hours.
• Briefly press the Up button to set the duration to 12 hours.
The heating lamp turns on then turns off.
3) Press the my button until the heating lamp turns on then turns off.
The new setting is programmed.
2.6. TIPS AND ADVICE ON INSTALLATION
2.6.1. Questions on the io 2kW Heating Slim Receiver?
Observations
Pressing a button on the
control point has no effect on
the heating lamp
2.6.2. Replacing a lost or broken io control point
Attention
• This reset is carried out if all the io control points have been lost or broken.
• Only switch the power off twice to the io 2kW Heating Slim Receiver to be reset!
Copyright
©
2017 SOMFY ACTIVITES SA, Société Anonyme. All rights reserved.
Possible causes
The control point has not been
programmed in the io 2kW
Heating Slim Receiver.
The batteries in the control
point are low.
The control point used is not
compatible with the io 2kW
Heating Slim Receiver.
The power supply is faulty.
0.5 s
< 2 s
= 3 h
= 6 h
Solutions
Follow the commissioning
procedure (see 2.3.)
Replace the batteries, using the
same battery model.
Ensure the two products are
compatible.
Check the power supply.
EN
= 12 h
21