Gas Installation

Installation at High Altitude

This fireplace is tested and approved for installations at elevations of 0 - 4500 feet (0 - 1372 m) above sea level
using the standard burner orifice sizes . At the time of installation, it must be determined if the appliance needs to
be derated . Contact your local gas supplier for de-ration requirements for your area .
Derated installation consideration can start at 2000 feet (610 m) above sea level .
At higher elevations, the amount of BTU fuel value delivered must be reduced by either using gas that has been
derated by the gas company or by changing the burner orifice to a smaller size as regulated by the local authorities
having jurisdiction and by the (USA) National Fuel Gas Code NFPA 54/ANSI 2223 .1 - latest edition or in Canada, the
CAN/CSA-8149 .1 code - latest edition .

Gas Valve Access Door

! NOTE: This fireplace has a gas valve and control system that can be stretched up to 46" (1 .2 m) from the middle
of the fireplace and be put next to the access door location .
The access door can be placed on any side of the fireplace, below the non-combustible line . Do not place the gas
valve or controls above the level of the burner . If the fireplace is to sit low on the floor, the controls must be placed
outside the non-combustible zone or insulated from the heat of the fireplace .
The use of a 10" x 10" (254 x 254 mm) access door is highly recommended . If no access door is installed, it is
possible to access the gas valve from inside the fireplace by removing the outer screen and cover plate .
The access door can also be used as a lower air intake as long as the opening requirements are maintained . See "Air
Intake" section for details .
The access door can be concealed in many ways such as HVAC vent cover, removable tile connected with Velcro
straps and more .