Vent Termination
Minimum Combustible Clearances from Vent
•
Horizontal Vent Clearances
A minimum clearance of 3" (76 mm) to the top and 1" (26 mm) to the
sides and bottom of the vent pipe on all horizontal runs to combustibles is
required .
•
Vertical Vent Clearances
A minimum of 1" (26 mm) all around the vent pipe on all vertical runs to
combustibles is required except for clearances in appliance enclosures .
•
Horizontal vents must have a minimum ¼" (6 mm) rise per 1 foot towards
the termination .