Minimum Combustible Clearances From Vent - Faber FEG4916F Manuel D'instructions

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Vent Termination

Minimum Combustible Clearances from Vent

Horizontal Vent Clearances
A minimum clearance of 3" (76 mm) to the top and 1" (26 mm) to the
sides and bottom of the vent pipe on all horizontal runs to combustibles is
required .
Vertical Vent Clearances
A minimum of 1" (26 mm) all around the vent pipe on all vertical runs to
combustibles is required except for clearances in appliance enclosures .
Horizontal vents must have a minimum ¼" (6 mm) rise per 1 foot towards
the termination .
Component Description
Wall Thimble
Wall Thimble (Small)
Wall Thimble (Universal)
Ceiling Support
Fire Stop
Wall Fire Stop
Vinyl Siding Standoff
Vinyl Siding Standoff (4 Pc . Kit)
Counter Flashing (Assembled)
Appliance Adaptor
For specific instructions on venting components visit the manufacturer's website listed below .
DuraVent Direct Vent Pro - www .duravent .com
Industrial Chimney Company (ICC) - www .icc-rsf .com
25
DirectVent Pro and iCC Compatible Vent Terminations
DirectVent Pro and iCC Compatible Vent Terminations
DuraVent Stock Number
58DVA-WT
58DVA-WTS
58DVA-WTU
58DVA-CS
58DVA-FS
58DVA-WFS
58DVA-VSS
58DVA-VSK
58DVA-CF
N/A - Provided with appliance
Offset
ICC Stock Number
TM-5WT
N/A
N/A
TM-5RDS
TM-5LS
TM-5TP
TM-VSS
TM-VSS
N/A
TM-5AA8
FaberFires.com

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Ffeg5316lFeg5316rFeg5716b

Table des Matières