Vent Termination

These instructions should be used as a guideline and do not supersede local codes
in any way . Install venting according to local codes, these instructions, the current
National Fuel Gas Code (ANSl-2223 .1) and/or Natural Gas and Propane Installation
Code, CSA B149 .1

Instructions

1 . Where a vent pipe passes through a floor or ceiling, a ceiling firestop MUST be used to retain insulation and
maintain proper clearances . Use roof support brackets where needed .
2 . Install the first section of vent pipe into the collar on top of the fireplace .
3 . Connections between each vent system component must be tightly joined and secured . Follow the vent
manufacturer's instructions for information on how to seal and secure vent and vent connections .
4 . Horizontal runs of vent pipe must be supported to prevent any downward sags . Horizontal pipe sections should
be supported at least every 4 feet . Wall straps can be used for this purpose .
5 . When installing the vent pipe, make sure that the vent pipe is supported by the structural/frame surrounding
and not by fireplace .
Follow the vent manufacturer's instruction for information on how to install, seal, and secure vent and vent
connections .
Framing for vents in combustible walls and ceilings:
When passing through combustible walls and ceilings, framing will depend on the type of vent installation −
horizontal or vertical . Ensure that the insulation is kept clear of the vent pipe using either a wall thimble or an attic
insulation shield . Follow the installation instructions supplied with the individual venting components .
Approved Pipe - This appliance is approved for use with M&G DuraVent or ICC venting .
DO NOT mix pipe, fittings or joining methods from different manufacturers .
For detailed chimney installation information please use the manufacturer's direct vent installation manual .
DO NOT pack insulation around the vent . Insulation must be kept back from the pipe to prevent overheating .
ALWAYS maintain specified clearances around venting and firestop systems . Install wall shield and ceiling
firestops as specified .

Vent Size

The fireplace will require a 5" × 8" vent .
Models
FEG4916F
FEG5316L
FEG5316R
FEG5716B
!
Vent Size
5x8
WARNING