Working the boiler
Adjust the ambient thermostat to the required temperature (approx.
20 °C). If there is a demand for heating water, the boiler starts
and the
symbol is shown on the display (fi g. 22). The boiler
will remain working until the set temperatures are reached, after
which it will go on stand-by. In the event of ignition or operating
faults, the boiler will perform a "safety stop".
The fl ame symbol
will go out and the fault code and
be displayed (fi g. 23). For a description of faults and how to reset
them, consult chapter "Troubleshooting".
Fig. 22
Fig. 23

Switching off

Switching off for short periods
For brief absences press the
display will show two segments in the central area (fi g. 17). When
the boiler remains powered with the gas tap open, it is protected
by the following systems:
- anti-freeze (fi g. 24): when the temperature of the water in the
boiler falls below safety values, the circulator and the burner
work at minimum power to increase the water temperature to
a safe value (35 °C). The
Fig. 24
- circulator anti-block: one operating cycle is performed every
24 hours.
Switching off for long periods
For prolonged absences press the
(fi g. 17). The display will show two segments in the central area.
Turn the main switch to "off".
Turn off the gas tap under the boiler by turning it clockwise (fi g. 25).
closed
Fig. 25
In this case, the anti-freeze and anti-block systems are di-
sabled.
Empty the water circuit or suitably protect it with a good make
of anti-freeze. Drain the domestic hot water circuit.
Boiler functions
Semi-automatic fi lling
The boiler features a semi-automatic fi lling device which turns on
by pressing the
button when the corresponding symbol
shown on the display (fi g. 26).
Fig. 26
button to switch off the boiler. The
symbol lights up on the display.
button to switch off the boiler
tap
If this condition occurs it means that the system is incorrectly
pressurised though the boiler will continue to work regularly. Press
the circuit fi lling button
Press the circuit fi lling button
fi lling sequence. During fi lling, the drops of the circuit fi lling symbol
and the growing pressure value appear on the display in a
cascade sequence (fi g. 27).
will
Fig. 27
After fi lling, the
symbol is displayed for a few moments and
then turns off.
Note
During fi lling, the boiler does not perform other functions. For
example, if there is a request for domestic hot water, the boiler is
unable to provide it until fi lling has fi nished.
Note
If circuit pressure reaches 0.6 bar, the pressure value fl ashes
on the display (fi g. 28b); if it falls below a minimum safety value
(0.3 bar), fault code 41 appears on the display (fi g. 28a) for a
certain time, following which, if the fault persists, fault code 40
is displayed (see chapter on "Troubleshooting").
Fig. 28a
Fig. 28b
In the event of fault 40, press
fi lling the circuit. If you have to fi ll the system several times, con-
tact the Technical Service Centre to check whether the heating
circuit is watertight (see if there are any leaks).
Information
Press , the display turns off and just the word InFO appears (fi g.
29). Press the button
button again to move on to the next piece of information. If the
button is not pressed, the system automatically exits the function.
Info list:
Info 0
shows the word InFO (fi g. 29)
Fig. 29
Info 1
only with the external probe connected, displays external
temperature (e.g. 12 °C) (fi g. 30).
The values shown on the display range between - 40 °C
and 40 °C.
Beyond these values the display shows "- -"
is
Fig. 30
14
to start-up the fi lling sequence.
a second time to interrupt the
to reset and then
to view operating information. Press the
to start