ENG
completed or the switch is pressed again.
• If the parameter d2 has been programmed with a value greater than 0 the pump may not
be activated until this time has elapsed.
• Massage and inhibition time are independent for each switch.
127
Air massage pump(s)
Water massage
Light (option)
remote activation
pump(s) remote
activation
5.5. System fixed features
This System has configured default parameters that can not be changed by the user.
HEATER ACTIVATION
The heater will start/stop when the real temperature has a deviation of more than 1ºC
compared to the scheduled one. (Hysteresis value). The system checks water temperature
automatically every 30 minutes
ANTI-STAGNATION SYSTEM
If the massage function has not been activated for more than 12 hours the system will
automatically switch on massage and blower pumps for 30 minutes to prevent possible
water stagnation.
OZONATOR
The ozonator (optional device) is active for 20 minutes and inactive for 10 minutes when
the filtration pump is working.
It is disabled if a massage or a blower pump is active except when these pumps have
been activated automatically by the system (Anti-stagnation system every 12 hours).
ANTI-FREEZING
In order to avoid cool external temperatures from freezing the water inside the hydraulic
27