Hydraulic Connection; Kit Installation - Iberspa 43639 Manuel D'utilisation

Masquer les pouces Voir aussi pour 43639:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 66
LIGHT
Connect directly to the M6 output of the PCB. Can be switched off or on from the front
control panel of the electrical box.
M6
K1
E5
SAT
J4
OTHER ELECTRICAL CONNECTIONS
• Connect the three level sensors supplied with the balance tank directly to the M9 input
of the PCB.
• Connect ozone wire directly to the grid 5-6 input of the electrical box.
• Connect the electric control box to the power supply.
ATTENTION
Make sure all the hydraulic and electrical / electronical connections are done
before connecting the electric control box to the power supply.
It is mandatory to use packing glands for all the connections coming out of the
cabinet and the junction box, and to use terminals in all connections in order
to preserve the integrity of the leads.

4.4. Hydraulic connection

KIT INSTALLATION

The compact kit must be below the Spa level. This avoids having to prime the pumps. The
maximum difference in level is 2 metres below (h ≤2m).
V1
M6
V1
F6
2SAT
h
2m
ENG
121
122
15

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

16412ce04015ce05135ce

Table des Matières