Errors/Causes/Troubleshooting - Winkhaus blueMatic EAV Instructions D'installation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

blueMatic EAV
EN
5

Errors/causes/troubleshooting

Error
Tappet does not
make optimal
contact with the
contact surfaces
5
of the frame part
No electrical
function (tappet
contact)
No electrical
function (frame
power supply)
Aug. Winkhaus GmbH & Co. KG ∙ Berkeser Straße 6 ∙ 98617 Meiningen
T +49  369  3950 - 0 ∙ www.winkhaus.de ∙ Subject to technical changes
STK/RNT
Possible cause
• e.g. hinge pivot
point not optimal
(concealed hinges,
etc.) or minimum
airgap (< 4 mm)
• Frame to sash
part position not
optimal
• Polarity reversed
• Corroded contact
surfaces
• Input voltage
connection
not correct
• or powerpack
supply overheated
52
Rectification
- Check airgap / hinge pivot
point and use spacer plate,
if necessary (installation
between face plate and sash
part)
- Check frame part in relation
to sash part positioning
- The centre mark of the
frame and sash part must not
deviate by more than ± 2 mm
vertically
- Check the frame part and
sash part polarity (see
respective mark with + (plus)
or - (minus) symbol and geo-
metric alignment)
- Check for cleanliness/cor-
rosion, refer to frame part
contact surfaces or tappet tip
and grease, if applicable
- Frame power supply input-si-
de connection
(test 230 V AC)
DANGER! Work on electrical
components requires expert
knowledge; all work should
thus be performed by quali-
fied electricians.
- Determine the cause for hea-
ting up (e.g. eliminate consu-
mers with > 1.5 A of continuous
load, reduce door temperature
by providing shade)
5051251