Drive Assembly Removal And Installation - Pentair STA-RITE INTELLIFLO VSD Serie Manuel D'installation Et D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 118
36

Drive Assembly Removal and Installation

WARNING
CAUTION
To remove the IntelliFlo
1. Be sure all electrical breakers and switches are turned off before removing the drive.
2. Disconnect the RS-485 communication cable from the pump.
3. Open the control panel cover.
4. Remove the three Phillips head screws securing the drive to the motor assembly as shown.
5. Lift up the drive assembly and remove it from the motor adapter located on top of the motor
assembly.
Note: Be careful not to remove the gasket between the drive and motor, it is critical in keeping
moisture out of the drive and motor. Replace the gasket if damaged. Do not reassemble with a
damaged or missing gasket.
To install the IntelliFlo
1. Be sure all electrical breakers and switches are turned off before installing the drive.
2. Be sure that the gasket between the drive and motor is in place. It is critical in keeping moisture
out of the drive and motor. Replace the gasket if damaged. Do not reassemble with a damaged or
missing gasket.
3. Verify that the three (3) orange motor post caps are in position before placing the drive on the
motor assembly.
4. Align the drive assembly with the motor adapter and seat the drive on the motor assembly.
5. Secure and tighten the drive assembly with the three Phillips head screws.
Note: Do not remove
Orange Motor Post
Caps (QTY. 3)
To avoid dangerous or fatal electrical shock hazard, switch OFF power to motor before
-
working on pump or motor.
To avoid electrical hazard, do not remove the four tamper proof bits from the motor assembly.
-
drive and control panel from the motor assembly:
®
drive assembly onto the motor assembly:
®
Phillips Head Screw
these screws
Phillips Head Screws
Adapter Connector
Gasket

Publicité

Table des Matières
loading

Table des Matières