Pump Strainer Basket Service (Continued)
10. Be sure that the lid o-ring is properly placed. Seat the locking ring and lid then turn clockwise
until the handles are horizontal as shown.
11. Reconnect the communication cable to the pump if required.
12. Switch the power ON at the circuit breaker. Reset the pool time clock to the correct time.
WARNING
13. Open the manual air relief valve on top of the filter.
14. Stand clear of the filter. Press the Start button on the pump.
15. Bleed air from the filter until a steady stream of water comes out.
16. Close the manual air relief valve.

Motor Service

1. Protect from heat:
Shade the motor and controller from the sun.
Any enclosure must be well ventilated to prevent overheating. Particular attention should be
paid to the motor fan cover and the cooling fins between the drive and the motor.
Provide ample cross ventilation.
2. Protect against dirt:
Protect from any foreign matter or splashing water.
Do not store (or spill) pool chemicals near the motor.
Avoid sweeping or stirring up dust near the motor while it is operating.
If a motor has been damaged by dirt it voids the motor warranty.
3. Protect against moisture:
Protect from splashing pool water.
Protect from the weather.
Protect from lawn sprinklers.
If a motor has become wet, let it dry before operating. Do not allow the pump to operate if it
has been flooded.
If a motor has been damaged by water it voids the motor warranty.
Note: Do not wrap motor and controller with plastic or other air tight materials during winter
storage. The motor and controller may be covered during a storm, winter storage, etc., but never
when operating or expecting operation.
FILTER OPERATES UNDER HIGH PRESSURE. WHEN ANY PART
OF THE CIRCULATING SYSTEM (e.g., LOCK RING, PUMP, FILTER,
VALVES, ETC.) IS SERVICED, AIR CAN ENTER THE SYSTEM AND
BECOME PRESSURIZED. PRESSURIZED AIR CAN CAUSE THE LID
TO BLOW OFF WHICH CAN RESULT IN SEVERE INJURY, DEATH,
OR PROPERTY DAMAGE. TO AVOID THIS POTENTIAL HAZARD,
FOLLOW THESE INSTRUCTIONS.
Clamp
Lid
Volute
Top view