23
Priming
(Continued)
To access the Priming menu:
1. Check that the green power LED is on and press the Menu button. "Settings" is displayed.
2. Use the Down arrow button to scroll to "Priming".
3. Press the Select button. The factory default is set to priming "Enabled".
4. To disable priming, press the Select button.
5. Use the Up arrow button. "Disabled" is displayed.
6. Press the Enter button.
7. Press the Down arrow button. Screen will read "Max Priming Time". The factory default is
set to 11 minutes.
8. Press the Select button to change the setting. The cursor will highlight the minutes column.
9. Use the Up or Down arrow button to change the time from 1 minute to 30 minutes.
10. Press the Enter button to save the setting.
11. Press the Down arrow button. The screen will read "Primed Sensitivity". The default for
this setting being "1".
12. Press the Select button to change the setting. The cursor will highlight the number.
13. Use the Up or Down arrow button to change the time from 1% to 100%. Increasing the
number makes the Priming less sensitive.
14. Press Enter to save.
15. Press the Down arrow button. Screen will read "Priming Delay". The default for this
setting is 20 seconds.
16. Press the Select button to change the Setting.
17. Use the Up or Down arrow button to change the setting from 1 second to 10 minutes.
Caution: Increasing the Priming Delay causes the pump to stay in the priming mode longer.
18. Press the Enter button to save the setting. Note: To cancel a change, press the Escape
button instead of the Enter button to exit without saving.
19. Press the Escape button to exit.

Disable Priming Feature on the Pump

When the IntelliFlo
on the pump cannot be disabled by the external automation control system only. If the IntelliFlo
pump is connected to an automation control system and priming is not desired, disable the priming
feature on the pump.
To disable priming with an automation control system:
1. Temporarily disconnect the RS-485 communication cable.
2. Open the LCD screen lid to disable priming on the pump. Press the MENU button, use the
arrow buttons to scroll and select "Priming", then select "Disabled" (the factory default is
set to "Enabled"). Press Escape to exit the menu.
3. Once priming is disabled, reinstall the RS-485 communication cable.