Drive Assembly Removal And Installation - Pentair STA-RITE IntelliFlo WhisperFlo VS Guide De L'utilisateur Et D'installation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 71

Drive Assembly Removal and Installation

To remove the IntelliFlo
1. Make sure all electrical breakers and switches are turned off before removing the drive.
2. Open the control panel cover.
3. Remove the three Phillips head screws securing the drive to the motor assembly as shown.
CAUTION: TO AVOID ELECTRICAL HAZARD, DO NOT REMOVE THE FOUR TAMPER
PROOF BITS FROM THE MOTOR ASSEMBLY
4. Lift up the drive assembly and remove it from the motor adapter located on top of the motor assembly.
Note: Be careful not to remove the gasket between the drive and motor, it is critical in keeping
moisture out of the drive and motor. Replace the gasket if damaged. Do not reassemble with a
damaged or missing gasket.
To install the IntelliFlo
1. Make sure all electrical breakers and switches are turned off before installing the drive.
2. Be sure that the gasket between the drive and motor is in place. It is critical in keeping moisture
out of the drive and motor. Replace the gasket if damaged. Do not reassemble with a damaged or
missing gasket.
3. Verify that the three (3) orange motor post caps are in position before placing the drive on the
motor assembly.
4. Align the drive assembly with the motor adapter and seat the drive on the motor assembly.
5. Secure and tighten the drive assembly with the three Phillips head screws.
Phillips head screw
Do not remove
these screws
Orange motor post
caps (QTY. 3)
An illustrated spare parts list can be found at:
www.pentairpooleurope.com
drive and control panel from the motor assembly:
®
drive assembly onto the motor assembly:
®
Phillips head screws
Gasket
Adapter connector
21

Publicité

Table des Matières
loading

Table des Matières