L.B. White Boss 400 DF Manuel Du Propriétaire Et Directives D'installation page 9

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

8. The heater must be regulated at all times for
proper operation.
9. For safety, this heater is equipped with a differen-
tial air pressure switch. Never operate the heater
with any safety device that has been bypassed.
Do not operate this heater unless this feature is
fully functioning.
10. Do not block air intakes or discharge outlets
of the heater. Doing so may cause improper
combustion or damage to heater components
leading to property damage.
11. The hose assembly shall be visually inspected
on a daily basis, after heater relocation, and
when the heater is in use. If it is evident there
is excessive abrasion or wear, or if the hose is
cut, it must be replaced prior to the heater being
put into operation. The hose assembly shall be
protected from building materials, and contact
with hot surfaces during use. The replacement
hose assembly shall be that specified by the
manufacturer. See parts list.
12. Check for gas leaks and proper function upon
heater installation, when relocating, and after
servicing. Refer to leak check instructions within
installation section of this manual.
13. This heater should be inspected for proper
operation by a qualified service person before
each use and at least annually.
14. Always turn off the gas supply to the heater if the
heater is not going to be used.
15. This heater is equipped with a three-prong
(grounding) plug for your protection against
shock hazard and must be plugged directly into
a properly grounded three-prong receptacle.
Failure to use a properly grounded receptacle
can result in electrical shock, personal injury,
or death.
16. If gas flow is interrupted and flame goes out, do
not relight the heater until you are that all gas
that may have accummulated has cleared away.
In any event, do not relight the heater for at least
5 minutes.
Boss DF Construction Heaters
17. When the heater is to be stored indoors, the
connection between the propane gas supply
container and the heater must be disconnected.
The container must be stored in accordance with
the Standard for the Storage and Handling of
Liquified Petroleum Gases, ANSI/NFPA 58, or
CSA B149.1, Natural Gas and Propane Gas
Installation Code.
18. Propane gas supply containers have left handed
threads. Always use the appropriate wrench to
make a connection to tighten or loosen the P.O.L.
fitting at the cylinders' gas supply valve.
19. Not for use with ductwork. DO NOT attach
any ducts to the heater's air inlet or hot air
discharge.
Owner's Manual • Boss DF
9

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Boss 1000 dfCh400Ch1000

Table des Matières