Special needs Manual
GB
GB
Connection to triphone basic electronics
5.2. Set-up example
In this example, the intercom buttons are located on the multi-key electronics circuit (pin header or
screw terminals connected).
Relay 1 (here: door opener) is activated for 10 seconds. The relevant pictograms are triggered during
events.
(40-0006 (Basic electronics- triphone), 40-0007, 40-0008, 40-0013 as well as 20-0061 (function
without 20-0061 not possible)
*0000
301 telephone no. Key 1 *800
(function waiting for the call to be answered
(no voice message) #
:
399 Telephone number Key 99 *800
(function waiting for the call to be answered
(no voice message) #
09 10 #
10 0 #
*
52
▸ Enter set-up mode
▸ Enter the telephone no. for the 1st Key
▸ Enter the telephone no. for the 99th Key (depending on
the amount of the connected key and the connection
position of the multi-key connection circuit (1-25) (26-50)
(51-75) (76-100 (set-up 300 corresponds to key 100))
▸ set the open door time interval (5 to 90 seconds)
▸ Set 0 as the code to open the door
▸ Exit set-up mode
www.behnke-online.com