Special needs Manual
GB
GB
Commissioning with analogue basic electronics
Code
Parameter
With version 1.34 or later:
*4** 1
*4** 2
*4* x y
*5* x y
*5** x
*6* 0
*6* x mm direct call button x (x=1..9) activate after mm (mm=00..99) minutes
*74
*75
*76
*77
Specify the number of long voice messages: Default setting: 1
50
* * * Number of long voice messages
1 = 1 message
2 = 2 messages
3 = 3 messages
no. 8: 10 s)
4 = 4 messages
10 s and message no. 9: 10 s)
The voice message module provides 5 short voice messages of up to 4 seconds
each. Additionally, the module will store longer voice messages of up to 40
seconds. Use this configuration step to divide these 40 seconds into 1 to 4 long
messages. The maximum amount of voices messages results from the five 5
messages and the set number of long messages, i.e. according to your configu-
ration you will either have 6 (5 short + 1 long) up to a maximum of 9 (5 short + 4
long) voice messages available.
Important: When changing the number of long messages, all previously
recorded messages will be erased; the short messages will not be erased.
40
in case relay 1 is activated
in case relay 2 is activated
check a variable (condition) (x=0..9, y=0..9) x=y?
The condition is fulfilled if value x equals value y.
set a variable (x=0..9, y=0..9) x:=y
sets the variable x to value y
increment variable (x=0..9) x++
increments the variable x (for x=9, the x++=0)
disable the timer
Disable Relay 1 (only for operations mode 18)
Enable Relay 1 (only for operations mode 18)
Disable Relay 2 (only for operations mode 18)
Enable Relay 2 (only for operations mode 18)
(message no. 6: 40 s)
(message no. 6: 20 s and message no. 7: 20 s)
(message no. 6: 15 s; message no. 7: 15 s and message
(message no. 6: 10 s; message no. 7: 10 s; message no. 8:
Confir-
mation
#
www.behnke-online.com