Commissioning with analogue basic electronics
3.5. Set-up example
In this example, the special needs module button is connected to the flat ribbon plug on T1. Relay 1
(here: door opener) is activated for 10 seconds. Messages 1, 2 and 6 are played during events.
*0000
21 telephone no. Button 1 #
09 10 #
10 0 #
53 4 #
56 5 #
58 1 2 6 #
In case this message will not be necessary, enter the following
setting: 58 1 2 0 #
*
3.6. Set-up example with function *800 (waiting for the call to be answered, here
without voice messages)
*0000
21 telephone no. Key 1 *800#
09 10#
10 0#
*
36
▸ Enter set-up mode
▸ Enter the telephone no. for the first button
▸ set the open door time interval (5 to 90 seconds)
▸ Set 0 as the code to open the door
▸ Play message 4 when opening the door
▸ Play message 5 when opening the door after a keypad
entry
▸ Play message 1 before establishing connection
Play message 2 while waiting for the call to be picked up
Play message 6 to the called party,
▸ Exit set-up mode
▸ Enter set-up mode
(00 can be replaced by voice messages,
see configuration steps from page 37)
▸ set the open door time interval (5 to 90 seconds)
▸ Set 0 as the code to open the door
▸ Exit set-up mode