Commissioning with analogue basic electronics

Commissioning with analogue basic electronics
coMMissioning with AnAlogue bAsic electronics
3.
3.1. 20-0001, 20-0002, 20-0043, 20-0041 in conjunction
with electronics add-on 20-0061
Connection
Telephone
system
Behnke Door intercom connection interface
Connections
Connect the open door function to relay 1
(only if required)
15 V= connect (absolutely necessary)
In case the camera is integrated into the door
intercom, please wire the video feed to a
monitor (where appropriate, interconnect the
video signal with relay 2 – see notice under
Seite 32)
Connect phone line (absolutely necessary)
34
34
Plug-in
Open door
power supply
function
(pot.-free)
Dimensions
Video
Signal
Power supply unit
Open door function
(on site)
Important: Please mind that you need to use a
separate power supply unit as well as a sepa-
rate a/b port for the telephone system for every
door intercom if you want to use several door
intercom systems (galvanic isolation – see also
basic electronics manual)!