Telecom Behnke 20-3117 Mode D'emploi page 39

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Code
Parameter
With version 1.30 or later:
*4 x
Condition
x=0
Always
x=1
Current time within schedule 1 (only makes sense with a clock
module in use)
x=2
Current time within schedule 2 (only makes sense with a clock
module in use)
x=3
Current time not within schedule 1 (only makes sense with a clock
module in use)
x=4
Current time not within schedule 2 (only makes sense with a clock
module in use)
x=5
For technical alarm (only makes sense with configuration step 17>0)
x=6
For non-technical alarm (only makes sense with configuration
step 17>0)
x=7
If alarm entry is enabled (only makes sense with configuration
step 17>0 )
x=8
If alarm entry is disabled (only makes sense with configuration
step 17>0)
x=9
Else (only makes sense with other *4x conditions having been set)
*5 x
Play message no. x (only makes sense with a message module
in use)
*5 0
Play signal sequence
*6 x
Display text no. x (only makes sense with a display module in use)
*7 x
Activate relays (1=Relay 1, 2=Relay 2, 3=Relays 1&2)
*8 x y
Wait for the call to be answered (x=voice message to be played while
waiting for the call to be answered and y=voice message to be
played after the call has been answered) (only makes sense with
an extension module in use)
*9 x
pointer to telephone number (x=1...9)
*9 0x
pointer to speed dial (x=00...99)
** x
individual group call (x=1=...9=next telephone number)
** 0
Hotline function
*#
Flash function
** **
stop dialling
** *0
Mute off
** *1
Mute on
www.behnke-online.com
Commissioning with analogue basic electronics
Special needs Manual
Confir-
mation
GB
39

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

21-311720-311821-3118

Table des Matières