Mating
Mating Mode
Mating
Procedure
Navigation
End
point
End
point
Failed mating
Press and hold for 10 seconds to reset
the serial number stored in DRC1.
Standard readings
Before use, the DRC1 must be mated with the CDF unit.
This section describes how to mate the DRC1 with the dehumidifier.
1. Insert batteries > Display flashes (if it does not flash, press the left button for 10 seconds and wait until
the display starts to flash)
The DRC1 will search for the dehumidifier for 2 minutes, during which time mating can take place in two ways:
2.a. Press the up and down buttons on the DRC1 at the same time for 5 seconds
2.b. Switch off the dehumidifier and wait for 5 seconds and then switch it on again-
Note: this must be done while the DRC1 is searching for the dehumidifier.
USB
RS485
EXT RH/T
3. The dehumidifier will send a serial number to the DRC1.
When mating is successful, the radio icon comes on.
4. The dehumidifier will confirm connection by showing code "Conn" for 3 seconds
More than one remote control panel can be connected to the dehumidifier.
ENTER press and hold for 3 seconds to enter user menu setup
UP and DOWN buttons to navigate between icons.
LEFT and RIGHT buttons allows to change set points value 1press = 1unit
ENTER confirms new set point value and automatically switches to next icon/or exits the menu
Press and hold RIGHT for 5 seconds to enter installer menu setup. ( Exit setup menu first)
When no button is pressed for 10 sec, the DRC1 exits the menu and returns to readings screen
If mating fails
and
Reset DRC1 and repeat mating process.
Standard readings when connected:
-Stand by, RH and ºC scale
-Compressor active, dehumidifying symbol on
RUN
FAIL
HEAT1 HEAT2
OK
ALARM
12V DC
is shown in the display and the radio symbol flashes
EN
35