US
5 Over Temperature Indicator
When the yellow led is lit, the working temperature has exceeded the normal values.
It is turned off when the temperature is normal.
6 Parts in Place (PIP)
When the yellow led is lit, it indicates that there is a parts-in-place error. This means
that no nozzle was detected, or that the electrode is not retracting properly. Turn off
the power. Check that the components are properly assembled, that they are free
from excessive damage, and that the electrode can slide back and forth with
comfortable pressure from one finger. Once the source of the error has been
corrected, turn on the power again.
7 Power ON Indicator
When the green led is lit, it indicates that the power is on.
8 Output current control
Adjustable from 30 to 50 A. For settings see cut data charts in the torch manual.
6.2.1

Symbol key

Power
Temperature
PIP
Parts in Place
4-stroke
bp23aa
Air
Fault
2-stroke
- 17 -