US
6.2
Control devices
1
Power switch 0/1
2
2/4 stroke
3
Air Pressure Indicator
4
Fault Indicator
1 Power switch
Turn the knob clockwise to "1" position for normal operation. Turn the knob
counterclockwise to switch "0".
2 2/4 stroke
When in 2-stroke cutting mode, the torch activates when the trigger is pressed, and
deactivates when the trigger is released. In 4-stroke mode, the torch activates on the
first trigger press, after which it can be released for increased comfort during long
cuts. The torch is then deactivated by pressing the trigger again.
3 Air Pressure Indicator
The yellow LED indicates that the air pressure is too low.
4 Fault Indicator
The blinking yellow LED indicates that the safety switch for the cover is activated and
the power is automatically turned off.
bp23aa
5
Over Temperature Indicator
6
Parts in Place (PIP)
7
Power ON Indicator
8
Output current control
- 16 -