Regulations:
• Machine compliant with European directives.
• The certificate of compliance is available on our website.
• EAC Conformity marking (Eurasian Economic Community)
Waste management:
• This product should be disposed of at an appropriate recycling
facility. Do not throw away in a domestic bin.
GENERAL DESCRIPTION
The GYSFLASH 4.12 is ideal to charge most lead-acid batteries, often used for cars and many other vehicles. These batteries can
be of many types eg: GEL (gel electrolyte), AGM (absorbed glass mat), WET, MF (Maintenance Free), CA (Calcium)...
This charger has been designed to charge 12V batteries (6*2V elements) from 1.2 Ah to 70 Ah, or for floating charge up to 130 Ah.
START UP
1. Connect the charger to the battery using the proper accessory (clamps, lugs, etc...).
2. Plug the charger to the mains (single phase 220-240Vac 50-60Hz).
3. Select the mode by pressing the
4. During the charge, the device indicates the charge's progress. When the indicator
ged.
5. The charge can be interrupted at any time by unplugging the mains plug or pressing the
6. After charging, disconnect the charger from the mains, then disconnect the charger's connections from the battery.
CHARGE MODE
• Modes and Options:
CHARGE mode (14.4V/0.8A) :
Mode designed for lead-acid batteries, 12V from 1.2 Ah to 15Ah. 7 step automatic maintenance cycle.
CHARGE mode with HOT option
Mode designed for lead-acid batteries, 12V from 15 Ah to 70 Ah and up to 130 Ah for floating charge. 7 step automa-
tic maintenance cycle.
CHARGE mode with COLD option
Modifies the charging voltage at 14.7V to charge the battery during cold weather (Less than 5°C) or for some AGM
batteries or batteries with caps.
• Charging curve :
The GYSFLASH 4.12 use an 7 step charging curve which guarantees optimal performance for your battery.
1
U
I
Analysis
CHARGE
OK
6
GYSFLASH 4.12
button. After roughly 5 seconds, the charge starts automatically.
(14.4V/4A) :
(14.7V/4A) :
2
3
4
Recovery
Test
Desulfation
Max 24h
stays on, the battery is completely char-
button.
5
6
Charge
Absorption
2h
EN
7
Floating
no limit