GENERAL DESCRIPTION

The GYSFLASH 4.12 is ideal to charge most lead-acid batteries, often used for cars and many other vehicles. These batteries can
be of many types eg: GEL (gel electrolyte), AGM (absorbed glass mat), WET, MF (Maintenance Free), CA (Calcium)...
This charger has been designed to charge 12V batteries (6*2V elements) from 1.2 Ah to 90 Ah, or for floating charge up to 130 Ah.
START UP
1. Connect the charger to the battery using the proper accessory (clamps, lugs, etc...).
2. Plug the charger to the mains (single phase 220-240Vac 50-60Hz).
3. Select the mode by pressing the
4. During the charge, the device indicates the charge's progress. When the indicator
vehicle. Once the indicator
5. The charge can be interrupted at any time by unplugging the mains plug or pressing the
6. After charging, disconnect the charger from the mains, then disconnect the charger's connections from the battery.
CHARGE MODES
• Modes and Options:
CHARGE mode (14.4V/0.8A) :
Mode designed for lead-acid batteries, 12V from 1.2 Ah to 15Ah. 7 step automatic maintenance cycle.
CHARGE mode (14.4V/4A) :
Mode designed for lead-acid batteries, 12V from 15 Ah to 90 Ah and up to 130 Ah for floating charge. 7 step automa-
tic maintenance cycle.
COLD/AGM Option (14.7V) :
Modifies the charging voltage at 14.7V to charge the battery during cold weather (Less than 5°C) or for some AGM
batteries or batteries with caps.
SUPPLY Mode (13.6 V/4 A):
This mode enables to use the charger as a stabilised power supply, with a voltage regulated at 13.6 V. This mode is
designed for providing a power supply to demonstration vehicles and can also be used to replace a vehicle's battery
while maintaining the system's memory. With this mode, there is no time limit.
When the
rent absorbed by the battery is higher than the charger's maximum current (4 A) and that the battery might end up
being discharged.
To access to this mode, press 5 seconds on the
mode selection light on. And after roughly 5 seconds, the charge starts automatically.

• Charging curve :

The GYSFLASH 4.12 use an 7 step charging curve which guarantees optimal performance for your battery.
1
U
I
Analysis
< 1s
CHARGE
OK
8
GYSFLASH 4.12
button. After roughly 5 seconds, the charge starts automatically.
stays on, the battery is completely charged.
indicator is on, the volyage is properly regulated. If the
2
3
4
Recovery
Test
Desulphation
max 5h
< 1s
max 12h
blinks, the battery is ready to start the
button.
indicator blinks, this means that the cur-
button. When this mode is selected, the three blue indicators for
5
6
Charge
Absorption
max 20h
max 8h
EN
7
Floating
no limit