General Description - GYS GYSFLASH 30.12 PL Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 1

GENERAL DESCRIPTION

The GYSFLASH 30.12 PL is designed to charge lead-acid batteries (Gel, AGM, Liquid, ...) and lithium of the Lithium Iron Phosphate
(LFP / LiFePO4).
This charger is suited for the charge of:
- Lead-acid batteries 12 V (6 elements in series) from 15 Ah to 375 Ah.
- LFP batteries 12V (4 elements in series) from 7 Ah to 375 Ah.
CALIBRATION CABLE
Procedure for the calibration of the charging leads in order for the charger to compensate any voltage drop due to the length or
condition of the cables. It is strongly recommended to perform this procedure each time the cables are modified or changed.
1. Before undertaking the procedure, make sure that the charger is disconnected from the mains socket.
2. Short-circuit the ends of the charging leads.
3. Press buttons
4. Plug in the mains plug while holding down the two buttons until the indicator light
Results :
- Indicator
is on: the calibration was successful.
- Indicator
is on: the calibration failed, disconnect the mains plug and restart the procedure.
5. Unplug the mains plug until the charger switches off.
START UP
1. Connect the charger to the battery.
2. Plug the charger to the mains (single phase 220-240Vac 50-60Hz).
3. Select the mode by pressing button
seconds, the charge starts automatically. By default, the charger starts on the last mode used, except when in Supply mode.
4. During the charge, the device indicates the charge progress. When indicator
Once indicator
stays on, the battery is fully charged.
5. The charge can be interrupted at any time by unplugging the mains plug or pressing the
6. After the charge, disconnect the charger from the mains, then disconnect the charger's connections from the battery.
CHARGE MODES
• Description of charging modes and currents :
*Lead battery corresponding : A lithium battery has a better starting performance (CCA) than a lead battery. That's why some
10
GYSFLASH 30.12 PL
The GYSFLASH 30.12 PL is equipped with an integrated temperature sensor that ensures that the char-
ging current is adapted to the ambient temperature for an optimal charging performance. This adjustment
ensures a highly precise charge, relative to the temperature of the room.
and
simultaneously.
Lead-acid CHARGE mode (14.6 V/30 A max.) :
Mode designed for the recharge of 12V lead-acid batteries from 15 Ah to 375 Ah. Automatic seven step
charge cycle.
Lithium CHARGE mode (14.4 V/30 A max.) :
Mode designed for the recharge of 12 V lithium batteries from 7 Ah to 375 Ah. Automatic eight step
charge cycle.
Some Lithium batteries incorporate a UVP protection (Under Voltage Protection) which
disconnect the battery in case of deep discharge. This protection prevents the charger from
detecting the battery. In order for the Gysflash 30.12 PL to be able to charge the battery, it
is necessary to deactivate the UVP protection. To do this, select the Lithium charging mode
and press the button
protection and automatically start charging.
Charging current 7 / 15 / 30 A :
Selection designed to choose the most suited charging current based on the type and size of the battery
(lead-acid or lithium).
Charging current
Pb
Battery capacity
LFP
, and the charging current by pressing button
for 10 seconds. The charger will then deactivate the UVP
7 A
15 A
15
60 Ah
60
100 Ah
7
15 Ah
15
30 Ah
(21
45 Ah EqPb*) (45
90 Ah EqPb*)
or
lights up.
. After roughly five
blinks, the battery is ready to start the vehicle.
button.
30 A
100
375 Ah
30
375 Ah
(90
1100 Ah EqPb*)
EN

Publicité

Table des Matières
loading

Table des Matières