Assembling The Welding Machine; How To Lift Up The System - CEA MAXI 405 Manuel D'instructions Et Pièces Détachées

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 14
Model
Three-phase power supply 50/60 Hz
Mains supply: Z
max
Power input @ I
Max
2
Delayed fuse (I
@ 60%)
2
Power factor / cosφ
Maximum efficiency degree
Open circuit voltage
№ of adjustments
Current range
Duty cycle @ 100% (40°C)
Duty cycle @ 60% (40°C)
Duty cycle @ 35% (40°C)
Wire diameter
Standards
Insulation class
Protection class
Dimensions
Weight
(*) IMPORTANT:
• This plant meets the requirements laid down in the EN/IEC 61000-
3-12 standard on harmonic currents.
• This system, tested according to EN/IEC 61000-3-3, meets the re-
quirements of EN/IEC 61000-3-11.
FIG. A
Table 1
MAXI 405
MAXI 505
V
230/400
Ω
(*)
kVA
19,0
24,2
A
35/20
40/25
0,96
0,97
η
0,75
0,71
V
20 ÷ 44
19 ÷ 51
20
30
A
60 ÷ 400
60 ÷ 500
A
230
300
A
300
370
A
400
500
mm
0,6 ÷ 1,6
0,8 ÷ 2,0
IEC 60974-1
IEC 60974-10
IP 23 S
H
mm
1060 - 780 - 600
kg
99
113

Assembling the welding machine

The standard composition of this welding installation consists
of:
• MAXI 405 or 505 generator.
• Earthing cable 4 m long (optional).
Accessories also include front and back wheels for moving
the welder, a chain for fastening the gas cylinder to the cylin-
der trolley easily, a handle especially for moving the machine
around manually, two eyebolts for lifting the machine off the
ground, a pivot to make sure the wire feeder is in the right po-
sition above the machine. Perform the following operations be-
fore using the machine:
• Open the case (box carton) and take out all the accessories
at the back of the welder.
• Mount the back wheels following the description given in
Fig. A.
• Unpack the welder system.
• Check that the welding apparatus is in good condition, other-
wise immediately inform the retailer or distributor.
• Check that all ventilation grilles are open and that no objects
obstruct the free passage of air.
• Lastly mount the handle, pivot and eyebolts following the de-
scription given in Fig. A.

How to lift up the system

Before lifting the unit, open the bag containing the eyebolts (at-
tached to machine), remove the two eyebolts complete with fi-
bre washers and mount them on the upper part of the cover.
IMPORTANT: Only lift the unit using the two eyebolts.
The wire-feeder has a handle and a hook so that it can be
hung up.
NOTE: The lifting and transporting devices conform with Eu-
ropean regulations. Do not use other equipment to lift or trans-
port the feeder.