MOUNTING OF THE RESIN CARTRIDGES

1
IN
2
1.
Remove the filter head cover.
2.
Remove the tubes from the two quick connectors (IN/OUT) on the unit head and
lift the entire cartridge assembly from the demineralizer base.
3.
Unscrew the two resin cartridge holders (by hand or with the use of the special
key).
4.
Remove the cartridges from their bag and place them into the holders (with the
cone-shaped side facing downwards and the word "UP" at the top).
5.
Place the o-rings in the groove of the resin cartridge holders and tighten holders
by hand (use only moderate force if you use the special key).
6.
Place the cartridge assembly back into the demineralizer base and fix it into place
with the use of the positioning rings.
7.
Reconnect the tubes to the IN and OUT connectors (make sure that the IN
connector is on the left hand side).
8.
Attach the filter head cover.
Dem 10
OUT
2
4
5
Figure 2
2
4
5
7