INNER FLEXIBLE DIAPHRAGM INSPECTION
1.
Remove the stylus.
2.
Use a C spanner to remove the probe
cap.
3.
For RP1/RP2: Remove metal eyelid and
spring. This will expose the inner flexible
diaphragm.
For RP1 DD/RP2 DD: Remove outer
flexible diaphragm by lifting away from
probe body to expose inner flexible
diaphragm.
4.
Wash the probe, using clean coolant (DO
NOT use sharp metal objects to clean out
debris).
5.
Inspect the inner diaphragm for signs of
piercing or damage. In the event of
damage return the probe to your supplier
for repair.
RE-ASSEMBLING THE PROBE MODULE
1.
For RP1/RP2: Re-fit the spring and the
metal eyelid.
2.
For RP1 DD/RP2 DD: Re-fit the outer
flexible diaphragm.
3.
Re-fit the probe cap. Tighten using the C
spanner.
4.
Re-fit the stylus.
DIAPHRAGM MAINTENANCE
Stylus assembly
Cap
Metal eyelid
C spanner