C. Detach the machine from its pallet by removing the 4 screws immobilising the machine
(fig.5).
D. Take the machine off the pallet. Please do this with at least two people in order to lower it
as gently as possible onto the floor.
E. Fit the frame onto its mounting, ensuring that the spring is on the correct side (fig.6).
After unpacking your machine, check that it has not been damaged in transit. Notify
us of any defects.
5.2

Positioning:

In order to achieve excellent performance and long-term reliability, choose a location that is:
Well ventilated, shielded from direct sunlight and away from sources of heat, with a flat and
sturdy surface free from vibration.
5.3

Electrical connection:

IMPORTANT: This machine must be earthed.
It is recommended that the system be protected with a fuse and an RCD.
Your mains electricity supply to the machine must be protected as indicated below:
- North America: 15 A protection;
- Rest of the world: 16 A protection.
For machines equipped with a variable speed drive, it is imperative that they be connected to a
junction box on a circuit fitted with a 300 mA RCD.
Note: Any problem resulting from any other type of connection will not be covered under warranty.
Before connecting your machine to the mains supply and in order to prevent the motor from burning
out when it is switched on, it is important to check that the mains supply matches the machine
specification (see machine nameplate).
This machine complies with Machinery Directives 2006/42, 2006/95, 2004/108 and is CE marked as
proof of this.
Please familiarise yourself with the safety pictograms displayed on the machine:
This pictogram indicates an electrocution hazard. Please isolate the machine
before carrying out any work on it. You will find it inside the machine on the
electrical enclosure. (fig.13, n°21)
You will find the circuit diagram for the machine inside the left-hand door of the
divider. (fig.13, n°22)